ChemLab v2.3 Evaluation Version requires Windows 95/98/ME/XP, Windows NT 3.51 or higher.

(v2.3, build 75 - June 9, 2003)

Model ChemLab requires Windows 9x/ME/XP/Windows NT 3.51 or higher to run. 
(MAC OS versions also available)


ChemLab is installed with an InstallShield self-extracting install program: setupex.exe
Executing setup.exe will start the install process and add a "ChemLab" menu to your 
start Programs menu.


Running chemlab.exe from windows 9x and NT4.0 

1. Click the Windows Start button, and then point to Programs. 
2. Select the ChemLab program in the ChemLab program group.*
2. When ChemLab starts pick a simulation module to load from the simulation dialogbox. 
3. Read the lab introduction in the introduction text window. 
4. After reading the lab introduction read the procedure. 
5. Select the procedure tab above the text window. 
6. Then perform the lab following the steps in the procedure. 

While performing the procedure you can record your observations in the observation text window.

*ChemLab may also be run by double clicking on the ChemLab.exe file found in the ChemLab 
program folder (c:\program files\Model Science\ChemLab\chemLab.exe)



Creating a UDL, with  the lab wizard involves the following steps:

1.  Select the ChemLab Wizard from the simulation dialog box (simulation dialogbox, 
	appears at startup or when the users specifies new reaction)
2.  From the File menu select "Create UDL..." menu.
3.  Lab Introduction dialog, displays copyright information (read and select Next) 
4.  Lab Information dialog, specify the File Name, Lab title and short lab 
	description (this information will appear later in the simulation dialogbox) 
	(fill in and select Next)
5.  Lab Documentation dialog, user specifies the introduction, procedure and results, 
	RTF (Rich Text Format)  files. To create these files user should first run Word or 
	other word processor and save the files in an RTF format. 
	(fill in all fields and select Next)
6.  Available chemicals dialog, the user specifies chemicals required for their lab from 
	a database of available chemicals.  
7.  The user may also add to or modify the chemical database, as they need to. 
8.  Modifying the properties of Added Chemicals. Once chemicals are added from the 
	chemical database, their properties may be modified, this allows chemicals to be 
	marked as products or reactants (reactants will appear in the chemicals dialogbox within ChemLab). 
	(Add all chemicals and select Next)
9.  Reaction dialog, the user specifies reactions list. Start adding reactions by 
	selecting the "Add Reaction button". A reaction detail dialog will appear. 
	Name reaction and set any reaction conditions. A new entry will appear in 
	Reaction Tree. Drag and Drop Chemicals from the Available Chemical List to the 
	leaf nodes labeled "Reactants" and "Products". 
10.  A reaction chemical dialogbox will appear if successfully dropped, fill in the 
	coefficient for the chemical. Continue to drag and drop until you have the 
	complete balanced reaction. Once all the reactions have been added, select Next.
11.  Finish dialog, this is the last step in lab creation process, select Finish and 
	the UDL will be created (file.udl) in the ChemLab directory.
12.  Close and restart ChemLab, select your newly created lab from the Simulation dialog.


NOTE: The UDL(s) created with the evaluation version are not saved to file.




New Relase v2.3, build 75 - June 9, 2003:

Added Molar Volume of Hydrogen Gas Lab (GasH2.dll)
Added Compression of Air Gas Lab (Compress.udl)
Added Charles' Law Gas Lab (chgaslaw.udl) 
Added 60ml Gas Syringe with Pressure Gauge.
Added 60ml Sealed Gas Syringe. 
Added Inverted 50ml Gas Buret.
Updated lab equipment labels so that they can now support up to 3 characters (previous limit of 2 characters).
Corrected bug with PASTE in ChemLab not freeing memory and releasing clipboard.
Corrected Copying (and copying menu) from Introduction & Observation RTF Windows.
Corrected bug related to releasing of DataSet(s) during titration into new containers (without deleting old container). 


(release v2.2, build 67 - April 1, 2003):

Updated of stoic_ul.dll (build 23) - reaction corrected color change problem.


(New Version: v2.2, build 67 - Jan 24, 2003):

Added Double Replacement lab experiment.
Added Volumetric flasks (100 & 250 ml).
Added menu option to copy UDL files to ChemLab working directory.
Added masking of solid fills within lab containers.
Fixed problem with pouring of precipitates into flask with buchner funnel.
Fixed problem with eyedropper showing drips when a container is filled.

Update v1.4 of LabWizard:
Adds new option to attach PDB files to LabWizard UDL(s), this allows the user to view the
Molecular structure of a chemical using RasMol launched through ChemLab. 
New option to 'Always Test' color change option - allows a chemical to dictate the color of a solution 
even when a reaction has not occured. 
Fixed problem with resetting chemical state in Reaction chemical dialog.


(v2.1, build 62 - Dec 4, 2002):

Fix printing problems - lab containers with fill masks appear with black fill.
Fix problem with flask & pipet appearance with ice water (different from other containers).
Fix to RTF Introductions for conduct.dll, Salt.udl, HARD.UDL & AcidUkwn.dll to correct 
printing problem (multiple page breaks).
Corrected problem with high & electronic scale text label - when printed; partially cut off bottom portion of equipment.

(New version: v2.1, build 60 - October 2, 2002):


New Heat of Neutralization Lab added.
New XP toolbar & icons.
New Toolbar options settings.
New tip of the day dialog.
New temperature plot in titration curve.
Htmlhelp replaces Winhelp
Dataset is now saved with Lab file.
New extension to Lab file with header_ex added to file end (file cookie: "CL20WIN").
pH curve labeling corrected - axis were mislabeled.
UDL Lab editing now correctly reinitializes the lab documentation.
Corrected extraction with pipet & eye dropper from watch glass & evaporation dish.
Corrected bug related to opening lab files outside of ChemLab directory and then calling LoadLibary:
	Now calls LoadLibraryEx with LOAD_WITH_ALTERED_SEARCH_PATH.
Added Answer Key (for Pro version) to directory.
Changed Model Science web static text field to a web link, in about box.
Corrected title bar - for UDL(s) lab simulation name was missing. 

Updated - v1.3 of Lab Wizard with heat of reaction settings.
Added calorimeter option setting to Lab Wizard.
Added new temperature plot in titration curve.
Equilibrium bug corrected.
Corrected color problem in UDL engine - previously a color change could occur between individual reactions - now it can only occur after all the reactions have run. This caused a problem when a clock reaction was consuming the chemical that caused the color change - as in rate of reaction lab.



(v2.0j, build 48 - Aug 16, 2002):

Corrects problem with decanting liquid through buchner funnel. An occasional floating
point error resulted in strange behavior during filtering of solid matter. 


(v2.0i, build 46 - June 9, 2002):

Corrected Problem with ToolBar for XP (Changed frame background to COLOR_BTNFACE).
Added Manifest files for ChemLab & Peridoic Table. This will UI to use themes in XP.
Added larger ChemLab scientist icon in about dialog.


(v2.0h, build 44 - May 4, 2002):

Added context help for menu selections. When F1 is selected and menu is selected.
Disabled buttons (Water, Pour, Temp, Stirring rod) when appropriate lab object is not selected.
Buchner funnel button will now add a flask with funnel if no flask is selected.
Weighing button will now add a centigram balance if no lab object or object that cannot be weighed is selected.
Stirring Rod will now appear in an empty container (it will not move if contained is empty)
Added shopping cart button & menu for online registration - evaluation version only.
Added menu option for online demo.
Added ChemLab Help shortcut to ChemLab program menu.
Added ChemLab Uninstall shortcut to ChemLab program menu.
Fixed redrawing for Lab List bug in Lab Dialogbox.

(v2.0g, build 41 - Jan 16, 2002):

New flat ToolBar with pulldown menus (requires comctl32.dll v5.8 or greater)
Corrected drawing of 250 ml Erlenmeyer Flask in pouring orientation.
Corrected problem with deleting image from screen when scrolled to far right.

(v2.0f, build 41 - June 14, 2001):

New Lab: Dumas Method (Ideal Gas Law)
New equipment: Dumas bulb. 
Added new hot plate heat increment option in lab equipment option dialog.
Set hot plate default increments at 10 J/S.

(v2.0e, build 37 - March 2, 2001):

Added 2 new labs: Spectrophotometer Lab and Buffer Lab.
Added Spectrophometer with cuvette to ChemLab.
Added new Spectrophometer data setting to LabWizard.
Repositioned Titration Data Window to bottom right of screen.
Corrected numbering in balance lab procedure.
Updated AcidBase lab to include instruction for using Titration Curve Window. 

(v2.0d, build 33 - Jan 1, 2001):

Added 2 new labs: balance lab and weak acid titration.
Added new titration data window (allows the user to plot a pH curve while titrating - very cool).
Added new Lab Wizard version (v1.2): 
	Now solves equilibrium reactions.
	New options settings (for solubility and pH meter).
	Includes pH sensitive indicators.
	Additional maxiumum temperature reaction condition.
New sign-on lab graphic.
Corrected resource leak associated with unfreed brush for colored solutions. 

(v2.0c, build 26 - October 22, 2000):

Added reflux condenser to distillation equipment options.
Corrected default distillation behavior.
Corrected bug with deleting of Lab objections before combined objects.

(v2.0c - build 22):

Corrected Windows Resource leak introduced in build 21.
Note: This leak may cause Windows to hang and become unresponsive after a prolonged period of using ChemLab. 
 

(V2.0c, build 21):

Changed name of "Scales" menu to "Show weight" in equipment menu.
Added centigram, electronic and high precision electronic scales.
Added Pipet (10ml), pipet has mwnu options that allows it to extract and release liquid volumes.
Changed eye dropper to use same extract/release menu interface as pipet.
Added new transfer to new container procedure menu option.
Added RasMol v2.6b2 - Molecular viewer, along with sample pdb files (not included with evaluation version). 
Added RasMol menu option to Help menu also (not included with evaluation version). 

Corrected coloring of bromothymol blue indicator in acid/base labs
Corrected special problem with redrawing of combined container.
Corrected special problem with transfering of indicators between conatiners.


(v2.0a):

New Periodic Table application (Periodic.exe) with quiz feature (see menu "Help -> Periodic Table"). 
Added printer option setting.
Fixed bug which caused exception when printing with empty lab space. 

(v2.0)
Distillation Equipment setup.
Electrochemical cell setup (Available in registered versions only).
Eye Dropper.
Hotplate with Magnetic Stirrer.
Conductivity Meter (Available in registered versions only).
Metal Wire for Flame Lab Experiment (Available in registered versions only).
Printer Options to allow user to print out selected instructions or Lab Space.
Indicators option for Wizard created Labs.
RTF Windows now support OLE embedded objects, such as bitmaps and spreadsheets.
Enlarged Chemical Database.
Various bug fixes.

(See "About ChemLab.html" for more information on ChemLab's features)



Known Problem: 

The Updated Windows Common Control version 4.72:

Windows 95 and NT 4.0 users may experience a problem viewing the complete list of ChemLab 
simulations in the Lab Module DialogBox (see list of simulation modules at end of this file). 
This is likely due to an older Windows common control file (comctl32.dll) being present. 

Do not install if using Win98.

This control is also updated when IE4.0 is installed. 

Available from:

http://msdn.microsoft.com/developer/downloads/files/40Comupd.htm

Note: it will be necessary for users to reboot before utilizing this control. 

To check the version of your common control file:

Go to your Windows\System directory.
Right Mouse click on comctl32.dll file
Select Properties from Menu
Select Version tab and version
If you have a version older than 4.72 you may wish to install update file...
 


Some useful Tips:

1. The Right mouse button brings up a popup context menu when clicked on the lab window.

2. Ctrl + left or right arrow key changes the selection of lab equipment. 
   The Lab window must have the keyboard focus; click the right mouse key on the lab window.



Model Science Software
web:   http://modelscience.com
email: info@modelscience.com

Copyright Model Science Software 1994-2003
